ISCAMI 1: Integrated system for the Management and

Format: Paperback

Language: English

Format: PDF / Kindle / ePub

Size: 9.05 MB

Downloadable formats: PDF

The digital lines go through a rotary switch (RS), so that the ramp generator resets to zero (i.e. starts a new frame) after either 128, 256, 512, or 1024 counts (scan lines); corresponding to frame rates of 120, 60, 30 and 15 Hz at increasingly high vertical resolutions. Inspect and certify fiber end face quality at the push of a button, making your technicians instant fiber experts Help your technicians get it right the first time; drive best practices, improve quality of work, and optimize their workflow Easily connect to a T-BERD®/MTS-2000/4000/5800/6000A/8000v2, HST-3000, SMARTClassTM Fiber, Certifier40G, DSAM and CellAdvisor via USB without the need for any additional adapters or software.

Continue reading


Microscopy: A Very Short Introduction (Very Short

Format: Paperback

Language: English

Format: PDF / Kindle / ePub

Size: 9.92 MB

Downloadable formats: PDF

Equipped with 5 Heads for 5 persons observing at the Same Time with the features of Infinite Optical System, Effective illumination, LED Pointer and images Coherence, it is widely used in Clinic, Research and Teaching Demonstration. • 1 pc.of Compensation Free Trinocular Head, lnclined at 30°, 360° Rotatable, lnterpupilary Distance 48-75mm • 4 pcs. of Compensation Free Binocular Head, lnclined at 30°, 360° Rotatable, lnterpupilary Distance 48-75mm • Infinite PLAN Achromatic Objective 4x, 10x, 40x & 100x • Double Layers Mechanical Stage 185x142mm, Moving Range 75x55mm • Coaxial Coarse & Fine Focus Adjustment, Fine Division 0.002mm; All aluminum pressure diecasted body.

Continue reading


Ultrafast Phenomena in Semiconductors

Format: Hardcover

Language: English

Format: PDF / Kindle / ePub

Size: 11.46 MB

Downloadable formats: PDF

Microscope measuring offers the best resolution, the greatest optical versatility and the broadest range of magnifications of any optical measuring technique. Hold the camera against the eyepiece lens, keep it steady and you will be surprised at the clarity of the images you produce. Reichert microscope, stereo, with photo take-off and beam prism. 4 objective lenses: Reichert DK 5x eyepieces wide field, x/y stage each with built in micrometer, 100-240 vac 50/60 Hz, external light source (light source needs minor repair at bulb end, and needs a bulb).

Continue reading


7th WACBE World Congress on Bioengineering 2015: 6th to 8th

Format: Paperback

Language: English

Format: PDF / Kindle / ePub

Size: 7.43 MB

Downloadable formats: PDF

X/Y digital micrometer and moving stage for accurate measuring. 9 Inches HD screen (1280×800) real-time display and no need to connect to computer. Autofocus systems can correct focus drift in a timeframe of milliseconds, a clear advantage over software-based algorithms, which often take several seconds (and can produce significant phototoxicity and photobleaching). Microscope Digital Camera immediately transforms most biological ø23 mm eyetube microscopes into a new modern digital microscope.

Continue reading


Principles and Applications of Ion Scattering Spectrometry:

Format: Hardcover

Language: English

Format: PDF / Kindle / ePub

Size: 14.30 MB

Downloadable formats: PDF

The crushed glass fragment is mounted between a slide and cover-slip in a specially prepared and characterized silicone oil which is placed in the hot stage. Spectra can be exported as images and copied via the clipboard into other software packages. The sensor may be positioned together with the indentation tip (FIG. 6) or together with the sample (FIG. 7). What accessories do you use to change magnification on a telescope? A binocular head provides two eyepieces to allow viewing specimens with both eyes.

Continue reading


Thing Knowledge: A Philosophy of Scientific Instruments

Format: Hardcover

Language: English

Format: PDF / Kindle / ePub

Size: 8.59 MB

Downloadable formats: PDF

With this flexibility of design, it will easily comply with future changes in coal testing methods and your own experiments. Beta dicalcium silicate is metastable below 670°C and monoclinic, with an nx of 1.717, an ny of 1.722, and nz of 1.736 and parallel to b; birefringence is 0.019. Move the slide to center the specimen over the opening in the stage directly over the light source. 2. Phosphor bronze connection strips are so designed that when flexed a little, they are easily slipped over the pegs on baseboard, where there natural spring holds them in position and ensures good electrical contact.

Continue reading


Modern Instrumentation for Scientists and Engineers

Format: Paperback

Language: English

Format: PDF / Kindle / ePub

Size: 11.88 MB

Downloadable formats: PDF

The material and/or what you want to observe in that material determines the type slide to use. The fast mode provides the quickest open and close action sequence for which the shutter is capable. Record on the board the calibration of your assign microscope using the oil immersion objective. 9. Once the images are acquired, PCI Lab & Office provide a complete set of processing and display functions including image zooming, pseudo-coloring, brightness, contrast and gamma adjustment, color correction, smoothing, sharpening etc.

Continue reading


Microscopia: Great Art of Light & Shadow

Format: Print Length

Language: English

Format: PDF / Kindle / ePub

Size: 7.95 MB

Downloadable formats: PDF

An AFM operating in contact mode will penetrate the liquid layer to image the underlying surface, whereas in non-contact mode an AFM will oscillate above the adsorbed fluid layer to image both the liquid and surface. We are traders of Scientific Instruments and Laboratory Equipments, with ready stocks. The microscope has: – Two pairs of eyepieces x10 and x20 – x4, x10, x40, x100 RMS DIN standard objectives giving magnifications from x40 to x2000 – The objectives are parfocal – Mechanical stage with vernier scales – Separate coarse and fine focal point controls – Abbe condenser with iris diaphragm – LED illumination (on models purchased from 01/06/2013) with rechargeable battery alternative power in order that the microscope can be utilized away from the mains electricity supply for upto 24 hours – Field lens for even illumination There are a variety of extras to be had as well: – Photography adapter – Digital camera adapter – Measuring equipment and a very good aluminium attache case to keep your microscope clean and secure – The Apex Researcher Attache Case on Amazon.

Continue reading


Confocal Scanning Optical Microscopy and Related Imaging

Format: Hardcover

Language: English

Format: PDF / Kindle / ePub

Size: 11.01 MB

Downloadable formats: PDF

The donor absorption and emission spectra should have a minimal overlap in order to reduce the possibility of donor-to-donor self-transfer. Modern microscopes are equipped with infinity-corrected objectives that utilize a tube lens in the microscope body to form a parallel region of light waves into which optical accessories can be inserted without seriously affecting image quality. Microorganisms are measured with an ocular micrometer which is inserted into the one of the microscope eyepieces.

Continue reading


Near Field Microscopy and Near Field Optics

Format: Hardcover

Language: English

Format: PDF / Kindle / ePub

Size: 9.05 MB

Downloadable formats: PDF

Only when very thin objects with a microtome or samples are being observed is it suitable to increase the magnification. It consists of Abbe’s Double Prisms with the Thermostat, Compensator, Telescope Mirror, Limb, Graduated Sector, Reading Magnifier and Radical Arm which carriers a Vernier. Your instructor will let you know if you are required to complete any optional exercises in this lab. JEM 201:1-9, 2005. [ PDF ] 140.) Wei SH, Rosen H, Matheu MP, Sanna MG, Wang SK, Jo E, Wong CH, Parker I. and Cahalan MD.

Continue reading